WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : J1880  

    Curv-O-Mark Contour Jumbo Centring Head - 1” and Up Diameter
    J1880

    £60.04  EX VAT
    SSP Suggested Selling Price = £69.50  YOU SAVE £9.46
     Buy in 3 easy interest free payments of £20.01† with

    The Jumbo Centring Head assists with the setting of centre lines, establishing accurate angles and marks for butt-ins, location points inside pipes and tanks, laying out keyways, and measuring declivity. The jumbo head model can be used on 1" diameter pipes and up. This tool consists of an 8" Y-type head attached to an adjustable dial bubble protractor (DSL.) A spring-loaded hardened centring pin feature on this head eliminates the need for a hammer. Just make the alignment and press the trigger.

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure

    Related Items

    Contour Pipe Fit Up Tools FAQs

    Answers to common questions about precision pipe marking, centring, levelling and angle tools used by pipe fitters and pipe welders.

    Are the strong magnets in pipe levels and aligners a hazard?icon-minus-redicon-plus-red

    They can be. Strong magnets snap onto steel and onto each other with enough force to pinch or crush fingers, so guide them on and off steadily, keep your fingers clear of the gap and wear gloves with larger magnets. Keep them away from mechanical watches, bank cards and electronic equipment.

    Anyone with a pacemaker or similar implanted device should keep magnets away from it. Heart charity guidance is to keep anything with a magnetic field about six inches (15 cm) or more from the device, and to ask your doctor or pacing clinic if in doubt. Strong tool magnets may call for more distance, so check with the person's medical team and follow your own risk assessment.

    Which marker should I use to mark stainless steel pipe before welding?icon-minus-redicon-plus-red

    Use a marker whose maker certifies it as low in chlorides, halogens and sulphur. Makers of certified markers for stainless steel and other corrosion-resistant alloys publish limits such as a few hundred parts per million for halogens and for sulphur, and issue batch certificates, whereas ordinary workshop markers do not usually say what is in the ink.

    Keep a separate marker for stainless so it does not pick up contamination from carbon steel work, and check the data sheet for what it was made for. Follow your welding procedure or customer specification, which may name the approved materials, and keep marks clear of the weld preparation and clean them off the joint area before welding.

    Why is the diameter I measure not the same as the size the pipe is sold by?icon-minus-redicon-plus-red

    Pipe is designated by a nominal size, which is a name for the size rather than a measurement. For smaller sizes the real outside diameter is different from the nominal figure, and only at larger sizes do the two match, so measure the outside of the pipe, or check the standard's size table, before choosing a tool. Tools are normally rated by the range of pipe sizes they fit, so look at the range on the tool.

    For a given nominal size the outside diameter is fixed and the schedule changes the wall thickness, and so the bore. A heavier wall therefore still fits the same marking or centring tool. Metric and inch designations differ, so check which one the tool uses.

    How do I check that my level is still accurate?icon-minus-redicon-plus-red

    Use the end-for-end test, as level makers describe it. Place the level on a flat surface, mark one end and a spot along the side over the vial, and note where the bubble sits. Turn the level through 180 degrees end for end, line it up with the marks and read again. On an accurate level the bubble is in the same position both times.

    For a vertical vial, hold the level against a vertical flat surface and repeat the test by turning it side to side. If the level fails, follow the maker's instructions, because some have an adjustable vial and others do not. Recheck after any knock or drop.

    Shop Similar Categories