WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE

ESAB Eco Air Parts

Sapre parts for ESAB eco air PAPR units

ESAB Sentinel A50 Air w/ Eco PAPR Parts FAQs

Spare cover lenses, filters, sweat bands and small parts for a powered-air welding helmet, and how to choose and look after them.

Which spares should I check regularly on a powered-air welding helmet?icon-minus-redicon-plus-red

Check the outer and inside cover lenses, the pre-filter, the main particle filter, the sweat bands and the face seal. These are the parts that get dirty, scratched or worn through normal use.

Also look over the breathing hose, the blower housing, the battery and the helmet shell for cracks, loose fittings and damage. RPE should be inspected before each use, and the key maintenance tasks for powered devices include changing filters, cleaning, and checking battery charge and airflow. Follow your manual for the parts list and suggested checks.

What are the signs that a cover lens needs replacing?icon-minus-redicon-plus-red

Look for cracks, scratches, pitting or dirt that will not wipe away. Welding-helmet manuals say to replace a scratched, cracked or pitted cover lens straight away, because it spoils your view of the weld.

The auto-darkening filter is meant to be used only with its inside cover lens fitted, as that lens protects the filter from dust and sweat. Keep the filter sensors and solar cells clean with a lint-free cloth, and avoid strong cleaning solutions. If the filter flickers or fails to darken, stop welding and check the shade and sensitivity settings and the battery before replacing parts; if that does not cure it, refer to the manual.

How can I tell that the particle filter needs changing?icon-minus-redicon-plus-red

Filters have a limited capacity and clog with use, so change them when the manual says and whenever they are damaged, visibly dirty or airflow falls. Signs include a low-airflow alarm, a loading indicator, noticeably shorter battery run time or less air felt inside the helmet.

For longer arc-welding tasks, powered equipment with a protection factor of at least 20 is the best option. The protection factor applies to the whole helmet, blower and filter combination, so only fit the filter type your maker specifies. Do not wash filters or blow them out.

Can I run the blower without the pre-filter or spark guard fitted?icon-minus-redicon-plus-red

No. Maker manuals say not to use a welding powered respirator without the spark guard cover, pre-filter and main filter all correctly installed. Without the spark guard, sparks may ignite the filter or damage it and let unfiltered air into the helmet.

The manuals also warn against using the helmet with the blower switched off or with filter parts missing, because oxygen can fall and carbon dioxide can build up inside the hood. Check the guard and filters before each shift, replace any that are burnt, clogged or torn, and leave the work area immediately if the airflow alarm sounds or the airflow drops.

How do I fit a filter correctly and check the airflow afterwards?icon-minus-redicon-plus-red

Switch the unit off, then fit the filter parts in the order and orientation shown in your manual, because the arrangement of main filter, pre-filter and spark guard cover differs between systems. Check any sealing gasket is clean and undamaged, the filter is fully seated and the cover closes properly.

Before each use, test the airflow with the flow indicator that comes with the system, as the manual describes, and check the alarm works. Check the fan is providing enough airflow before every use and never keep working if airflow drops or a warning device sounds. A loose or misaligned filter can let unfiltered air in.

The helmet's coin cell battery needs changing. What should I know?icon-minus-redicon-plus-red

Find the battery type and location in the manual, remove the old cell carefully and fit the new one the right way round. The helmet's battery indicator will normally show when a change is due, and the manual may suggest removing batteries before long storage.

Lithium coin cells are very dangerous if swallowed. A cell lodged in the foodpipe can cause severe tissue damage quickly, and a used cell can still hold enough charge to harm. Children under five are at most risk. Keep new and used cells out of reach, dispose of them properly, and get urgent medical help at once if you suspect one has been swallowed.