WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE

ESAB Consumables

ESAB Consumables FAQs

Practical answers on choosing, storing and using welding wire and stick electrodes.

How do I read the classification code on a stick electrode?icon-minus-redicon-plus-red

Most stick electrodes carry a classification code on the pack, for example a letter E followed by digits. Taking a common low hydrogen code as an example: E means a stick electrode, the first two digits give the minimum tensile strength of the weld metal, the next digit shows the positions it can be used in, and the last digit tells you about the coating type and the current it needs. Extra suffixes can show a hydrogen limit or better impact toughness.

Wire and rod codes follow their own patterns, so read the maker's data sheet or the standard named on the pack. Always match the code to the strength and type of the steel you are welding.

How do I choose the right MIG wire diameter and shielding gas?icon-minus-redicon-plus-red

Wire diameter and wire feed speed together set the welding current, because the wire burns off at a rate that settles in balance with the feed speed. Thicker material and higher current generally call for a larger diameter, while thin sheet suits finer wire. Your welder's manual and the wire data sheet show which diameters the machine is built for.

For steels, typical shielding gases are carbon dioxide or argon mixed with carbon dioxide or a little oxygen. Non-ferrous metals normally use argon. The right gas depends on the wire, the metal and the transfer mode, so follow the wire maker's recommendation.

What is the difference between solid wire and flux-cored wire?icon-minus-redicon-plus-red

Solid wire is a single strand and needs an external shielding gas. It usually gives little spatter and no slag to chip off, which suits clean, thinner work where appearance matters. Flux-cored wire is a tube filled with flux. Some types still use gas, while self-shielded types do not, which helps outdoors where wind can blow gas away.

Flux-cored wire generally tolerates dirtier or scaled steel and is often chosen for thicker material and higher deposition, but with slag to remove afterwards. Neither is better in every case. Choose by thickness, location, gas supply and what your welder is designed to run.

How do I match a TIG filler rod to the metal I am welding?icon-minus-redicon-plus-red

The weld pool is a mixture of the parent metal and the filler, so the rod is normally chosen to suit the parent metal. Carbon steel, low alloy steel and stainless each have their own rods, and low alloy heat-resistant steels need a rod made for that alloy. Using a general-purpose rod on everything is a common mistake.

In TIG the filler is added to the weld pool by hand, separately from the arc, and argon is the usual gas for steels and stainless. Check the rod's data sheet or the standard named on its pack, and follow your welding procedure if the job is specified.

How should I store MIG wire so it feeds and welds well?icon-minus-redicon-plus-red

Moisture is the main enemy of solid wire. Rust on the surface can cause poor feeding and porosity in the weld, and wire damaged by moisture cannot be reconditioned. Keep reels in their original packaging in a clean, dry place until needed.

Wear clean gloves when handling wire, because bare hands can leave moisture on it. When a part-used reel is not in use, take it off the feeder and seal it in a clean plastic bag; if it must stay on the machine, cover it securely. Keep it away from grit, oil and dust from cutting or gouging.

Why are low hydrogen electrodes supplied in sealed packs?icon-minus-redicon-plus-red

Low hydrogen electrodes are used where hydrogen cracking in the weld or heat affected zone must be avoided, such as on critical or more hardenable steels. Their coating picks up moisture from the air, which adds hydrogen to the weld. Sealed packs let you use them straight from the pack, with no baking needed beforehand.

If a pack has been opened or damaged, the electrodes should be re-dried as the maker instructs and then kept warm or limited in their exposure time. Exact temperatures and times differ between makers, so follow the instructions on the pack and your job specification.