Inflatable Twin Purge Bags

Inflatable Twin Purge Bags FAQs

Answers to common questions about choosing, positioning and using inflatable twin purge bag systems for back purging pipe welds.

How does an inflatable twin purge bag system work?icon-minus-redicon-plus-red

A twin purge bag system is two inflatable bags joined by a spinal tube. You position one bag on each side of the weld joint inside the pipe, then connect the purge gas. The gas inflates the bags so they seal against the pipe bore, and once a preset pressure is reached a valve releases gas into the small space between them.

Because only that short section is purged, the volume of gas to be displaced is small, so the purge is usually much quicker than filling the whole pipe. Air leaves through exhaust tubes built into the bags. The same gas connection normally handles both inflation and purging, so check the maker's instructions for your system.

How do I choose the right size of twin purge bag?icon-minus-redicon-plus-red

Choose by the internal diameter (bore) of the pipe, not just its nominal size. Pipe of the same nominal size can have a different bore depending on wall thickness, and each bag size only seals properly across a stated range of internal diameters.

Measure the actual bore, then pick the bag whose working range covers it. A bag that is too small may not seal, and one that is too large can crease or be over-stretched. Fittings such as elbows and tees can change the bore at the joint, so measure there too. Always check the data sheet for the range that applies to your system.

Where should I position the bags in relation to the weld?icon-minus-redicon-plus-red

The bags need to sit either side of the joint, far enough away that the heat of welding does not damage them but close enough that the purge volume stays small and the purge is quick. A luminous strip or marker on the system lets you centre it on the weld gap by looking through the joint gap.

The right distance depends on the pipe size, the heat input and the maker's guidance, so follow the instructions for your bags. Keep the bags clear of tack welds and any sharp edges or burrs on the bore, as these can damage the material.

Do I need an oxygen monitor when using purge bags?icon-minus-redicon-plus-red

It is strongly recommended. Time-based purging is only a rough guide, because leaks, joint gaps and pipe volume all affect how quickly air is displaced. A purpose-made oxygen monitor connected to the exhaust or purge space shows when the oxygen level is low enough to start welding.

The oxygen level you need depends on the material, the weld specification and your procedure, so work to the figure in your welding procedure rather than a general rule. The monitor can also tell you when it is safe to reduce the gas flow once the target is reached.

Why must the weld gap be sealed before I start the purge?icon-minus-redicon-plus-red

Any open gap lets purge gas escape and air get drawn in, so the oxygen level stays high and the root can oxidise. Sealing the joint with purge tape or similar sealing tape keeps the gas in the purged space and helps the oxygen level fall.

Seal the full length of the joint, press the tape down firmly and keep it clear of the area being welded, then peel it back progressively as you weld. Joints with a root gap or poor fit-up leak more, so take extra care with those. Use tape that is suitable for the job and leaves no residue on the weld preparation.

What gas flow should I use to purge and weld?icon-minus-redicon-plus-red

Use a gentle, controlled flow. Too high a flow causes turbulence, which can draw air back in, and at the weld it can blow into the molten root. Many makers give a maximum inflation and purge flow for their bags, so do not exceed the figure on your data sheet.

A common approach is to purge at a higher setting until the oxygen monitor shows the target level, then reduce the flow before and during welding. The exact figures depend on the pipe size, the gas, your procedure and the equipment, so follow the maker's instructions and your welding procedure specification.