WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE

Invertec V205 S

Invertec V205 S FAQs

Accessories for a portable inverter welder used for TIG and stick welding: gas flowmeters, hand remote controls and cable kits.

Where should I put the return clamp?icon-minus-redicon-plus-red

The welding return clamp should be connected directly to the workpiece, as close as practical to the weld or to the work bench. A poor return path adds resistance, which can cause an unstable arc and heating at the connection.

Clean the spot first so the clamp bites into bare metal, not paint, scale or spatter. Check the clamp spring is still firm, that the cable is fixed tightly into the clamp, and that the clamp is suited to the current you are welding at. Re-check the connection after any reconnection, and never let the current pass through bearings, chains or other parts of the machine on its way back.

What should I check on the cables and electrode holder each day?icon-minus-redicon-plus-red

The welder should check the cable, electrode holder and coupling devices every day, and report any faults. Look for cuts, crushed or hardened insulation, loose or hot connections, damaged holder jaws and cracked holder insulation. Do not use a lead or holder with exposed conductor or damaged insulation; repair or replace it.

In stick welding, isolate the holder before changing the electrode, because relying on a glove alone against the open circuit voltage can be unsafe, particularly if gloves are damp. Dry gloves and an all-insulated holder help, and your risk assessment sets the rest.

Is argon a hazard when welding?icon-minus-redicon-plus-red

Yes, in the wrong place. Argon is heavier than air, has no colour or smell, and can collect in low-lying areas, tanks and fabrications. Where air is replaced by gas, unconsciousness can come within seconds, with little warning of breathlessness. Shielding gas can even enter a fabrication through the weld root during external welding.

The main control is to avoid entering such spaces. If entry cannot be avoided, the space must be tested from outside with a calibrated oxygen meter and suitable emergency arrangements made. Do not rely on the gas sinking or rising, and never add oxygen to improve the air.

What argon flow rate should I set for TIG welding?icon-minus-redicon-plus-red

It depends on the nozzle size, welding current, joint type and draughts, so treat any figure as a starting point. Flow figures in general guides are only a starting point.

Larger cups and gas lenses usually need more, and fine low-current work often needs less. Follow the torch and welder manufacturer's guidance and adjust on test pieces. The flowmeter must be the right type for argon, because its scale is calibrated for a particular gas, and a flow tester at the torch cup will show the real flow.

Does more gas flow give better protection?icon-minus-redicon-plus-red

No. Too much flow can cause turbulence at the cup, which pulls air from around the weld into the gas stream and contaminates the weld. Excess flow also uses gas faster for no benefit.

If you have porosity, a dull or discoloured weld or tungsten problems, do not just turn the flow up. Check for draughts, a damaged or loose torch cup, wet or contaminated hose, a leak and the gas lens or cup size. Set the flow to the guidance for your torch, then change one thing at a time.

How can I check for gas leaks between the cylinder and the torch?icon-minus-redicon-plus-red

Leaks waste gas and let air into the weld. One way is to hold a flow tester over the torch cup and compare its reading with the flowmeter; a clear difference points to a leak in the machine, hose or torch lead.

Also check each connection with a leak detection fluid made for the purpose and recommended by your gas supplier, and tighten or reseat any that bubble. Do not use washing-up liquid or soapy water, because they can contain oils and can damage fittings. Close the cylinder valve and check the pressure gauge does not fall over time when the system is idle. Replace cracked hoses and worn seals.