0 items in your basket
Total £ 0.00 EX VAT
SHOPS
Special Buys/Offers
Rapid Merchandise Shop
PATON Shop
GoGrid Shop
GasiQ Shop
CK Shop
Furick TIG Shop
GPPH Shop
Kemppi Shop
Spiderhand Shop
Optrel Shop
3M Shop
Plymovent Fume Extraction
Miller Shop
Elga Shop
CEPRO Shop
Bohler Welding Shop
SFE Shop
Hypertherm Shop
Lincoln Electric Shop
ESAB Shop
Fronius Shop
HMT Shop
Gullco Shop
FEIN Shop
SAIT Shop
Harris Shop
FANUCI & FALCON Shop
Jackson Safety Shop
Key Plant Automation Shop
Orbitalum Shop
Bessey Shop
Bester Shop
EWM Shop
MACHINES
Welding Machine Offers
Arc Welders
MIG Welders
TIG Welders
Plasma Cutters
Air Compressors
Engine Driven Welders
Battery Power Supplies
Generators
Fume Extraction
Sub Arc Machines
Weld Positioning Equipment
Cutting Equipment
Spot Welders
Stud Welders
Used Machines
LC Laser Shop
ARC
MMA Electrodes
Cable Sets
Earth Clamps
Electrode Holders
Cable Connectors
Welding Cable
Welding Helmets
Arc Accessories
Rod Ovens
Learning
Exothermic Cutting
Chemical Aids
Gouging
MIG
MIG Filler Wire
MIG Torches & Parts
Site Wire Feeders
MIG Regulators
Ceramic Backing Tiles
MIG Accessories
TIG
TIG Torches
TIG Torch Parts
Tungsten Electrodes
TIG Filler Wire
Machine Remotes
TIG Accessories
Cold Wire Feeders
TIG Gauntlets
Tungsten Sharpening
Weld Cleaning
Gas Purging Tools
LASER
Laser Welders
Laser Cleaners
Laser Accessories
PLASMA
Plasma Torches
Plasma Torch Consumables
Lincoln Cutting Tables
GAS
Cutting & Welding Outfits
Gas Regulators
Flashback Arrestors
Gas Hoses & Fittings
Gas Torches
Gas Cutting Nozzles
Gas Welding & Heating Nozzles
Gas Accessories
Gas Welding & Brazing Rods
Gas Bottle Trolleys
Gas Cutting Machines
Quick Action Couplings
Regulator Accessories
Gas Analysers
SAFETY
Helmet Spares
Air Fed Welding Helmets
Swiss Air System
Goggles
Welding Blankets
Spectacles
Visors
Welding Curtains
Ear Protection
Safety Helmets
Monkey Masks
Gloves
Caps & Hoods
Leather Welding Clothing
Overalls
Weldline Female PPE
Disposable Masks & Respirators
WORKSHOP
Build your own GPPH Welding Table
Magnetic Drilling
Rapid Pipe Shop
Bevelling Machines
Automation
Metal Markers
Inspection Equipment
Pipework Equipment
Site Equipment
Exact Pipe Cutting Machines
Welding Rotators
Welding Tables
Bandsaws & Blades
TORCH &MACHINE SPARES
Pipe Cutting Machine Accessories
Parts for CO2 Laser
Kemppi MIG Parts
Machine Parts
Plasma Welding Torches
Water Coolers
Binzel MIG Parts
Tungsten Grinder Parts
WIRE, FLUX & RODS
Brazing Flux
Sub Arc Wire & Flux
ABRASIVES
3M Abrasives
SAIT Abrasives
Spectre Abrasives
Other Brand Abrasives
Backing Pads
Finishing & Polishing Products
Wire Brushes
Abrasive Belts
TOOLS
Angle Grinders
Right Lines Tool Offers
Magnetic Tools
Welding Clamps
Pipe Fit Up Tools
Site Storage
Orbitalum Pipe Machines
Orbitalum GF Sawblades
SECTORS
AGRICULTURAL
Education & Learning Centre
HOBBYIST
VEHICLE REPAIR
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Replacement filters, spark shields, hoses, head covers and fittings for a powered air-purifying welding helmet system, and how to choose the right ones.
Start with the label on the blower unit and the parts list in the manual. Makers say the blower label shows the helmet, hood and filters that make up the approved system, so use only the components listed there. Note any part number on the old item.HSE guidance says replacement parts should ideally come from the original manufacturer, so the equipment keeps performing as intended and gives the protection the maker states. Do not swap in an unlisted part to make something fit. If you cannot match a part from the label and the manual, ask our team before ordering.
The pre-filter is a coarse outer filter that protects the main particle filter behind it. HSE notes that some manufacturers recommend pre-filters for exactly this reason. The particle filter does the fine filtering that protects you from welding fume.The pre-filter is often the item changed more frequently, but how often depends on the maker, the work and the amount of fume, so follow the manual. Both must be the types listed for your blower. Particle filters do not remove welding gases, so they are no substitute for good ventilation and extraction.
HSE guidance says filters have limited capacity and can clog, and should be changed as the manufacturer instructs. Change one if it is damaged, visibly contaminated, past its shelf-life date, or breathing or airflow becomes harder. For filters on powered respirators, the maker sets the change interval, not a fixed figure that suits every system.Makers also describe a low-airflow alarm or a much shorter battery run time as cues to check the filters. Marking the fitting date on the filter helps you keep track. Do not wash, tap or blow out a filter to reuse it, because that can damage the filter element.
A spark shield (spark guard) covers the filter inlet. Maker instructions for powered welding respirators say not to use the unit without a properly installed spark guard, because welding sparks may ignite or damage the filter and let unfiltered air in.Replace it if it is deformed, burnt through, torn or no longer fits closely. Check it along with the filters before use. Use only the shield made for your blower, because a loose or wrong-fitting one can leave gaps. The material and design vary between systems, so follow the manual.
HSE says RPE must be thoroughly inspected before each use, and its guidance for powered respirators says to make sure any hoses are connected properly and never to use equipment that is damaged or incomplete. Look along the hose for cracks, splits, holes, kinks or stiffness, and check that the end fittings and seals are present and seat firmly.Replace a damaged or deformed hose rather than taping it, because leaks reduce the air reaching the helmet. Use the hose specified for your system and route it so it is not crushed or caught on the workpiece.
Use only the battery and charger the manufacturer specifies, and do not use a battery that is damaged. Follow the maker's storage, charging and care instructions, because battery condition affects how well a powered respirator performs.HSE guidance says the battery should be fully charged before use and that battery charge and flow rate are key maintenance checks. Batteries wear with use, so run time gradually shortens, but a clogged filter has the same effect. Storage and charging advice varies between makers, so follow your manual.