    Straight answers to the questions people ask most when finding and fitting spare parts for a downdraft extraction table.

    Which parts of a downdraft table wear out or fail most often?icon-minus-redicon-plus-red

    The parts that work hardest are the push buttons and switching elements, the relays and contactors, the fuses, and the fan motor with its fan wheel. Control components fail from heat, vibration, dust and repeated switching. Fuses blow when something else is wrong, such as a motor drawing too much current.

    Mechanical items such as adjustable feet can also be damaged by moving the table. Keep a note of what has failed, because repeated failure of the same part usually points to an underlying cause.

    Can I fit electrical spare parts myself?icon-minus-redicon-plus-red

    Only a competent person should work on the electrical parts of a table. That means someone with the training to isolate the supply safely, prove it is dead, work on the control circuit and test the unit afterwards. If your workplace has a maintenance electrician, they are the right person.

    Always isolate the table at its main switch and lock it off before opening any cover. Follow the wiring diagram in the manual, and have the unit checked before it goes back into use.

    Why does my table trip or blow fuses repeatedly?icon-minus-redicon-plus-red

    A fuse is the weakest link by design, so repeated blowing means something is overloading the circuit. Common causes are a failing motor, a jammed or damaged fan wheel, a wiring fault, a failing relay or a transformer problem.

    Do not fit a larger fuse to stop it happening, because that removes the protection and can start a fire. Use the rating and type specified for that position, and have a competent person find the cause before the table is used again.

    What is the difference between normally open and normally closed switching elements?icon-minus-redicon-plus-red

    A switching element is the contact block behind a push button. A normally open element completes the circuit only when the button is pressed, which is the usual arrangement for a start function. A normally closed element breaks the circuit when pressed, which is the usual arrangement for a stop function.

    If you fit the wrong type, the button will do the opposite of what its label says. Check the existing element before you replace it, and test the stop function carefully.