WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : 01-082-00X  

    Arcair Angle-Arc K4000 Extreme Manual Gouging Torch - 1000A
    01-082-00X

    Select Option 
    Prices From £266.70 ex VAT

    Arcair Angle-Arc Torches are highly efficient metal removal tools for fabrication jobs in steel fabrication plants, shipyards, railroads, farms........anywhere people want to save time and money.

    They speed up weld removal, back gouging, edge preparation, defect repair and many other metal removal jobs. They are ideal for almost all metals – with little or no deformation – because the heat input is so low.

    The Arcair Angle-Arc K4000 Extreme is a heavy-duty gouging torch operating to 1000 amps. Angle-Arc torches feature a natural 15° torch angle for greater operator comfort. Typical applications include heavy metal removal applications such as weld preparations in pressure vessel shops and shipyard fabrication.

    Specification
    Accepts: 4mm – 12.7mm Round Electrodes, 9.5mm & 15.9mm Flat Electrodes
    Amperage Range: 90 – 1000A
    Compressed Air Pressure: 80psi (5.6Kg/cm²)
    Compressed Air Flow Rate: 25cfm

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure
       Arcair Air Carbon-Arc Gouging Guide

    Gouging Torches FAQs

    Practical answers on choosing, setting up and looking after a carbon arc gouging torch that runs on compressed air.

    What does the amp rating on a gouging torch mean, and how do I match it to my job?icon-minus-redicon-plus-red

    The rating is the highest welding current the torch is designed to carry. You need a torch rated at or above the highest current you will run, and that current is set by the carbon size you use. As a guide, hand gouging typically runs from roughly 275 A on a 6.4 mm carbon up to roughly 550 A on a 13 mm carbon, so a larger carbon needs a higher-rated torch.

    Running a high-current carbon through an under-rated torch overheats the head and the air valve. Check the data plate or manual for the torch rating, and make sure your power source and cable can also supply the current you need.

    How far should the carbon stick out from the torch head?icon-minus-redicon-plus-red

    Keep the stick-out short enough that the carbon is held rigidly and the air stream stays close to the arc, but long enough to reach the work comfortably. Shorter generally gives steadier control, and the maker's instructions for your torch and carbon size give the permitted extension.

    As the carbon burns back, release it, slide it forward and re-clamp it. If the copper coating peels back a long way from the tip, the current may be too high for that carbon size or the stick-out too long, so reduce one of them. Always let the torch and carbon cool before adjusting by hand, and wear gloves.

    Why is my torch head or cable getting hot?icon-minus-redicon-plus-red

    Heat usually means the torch is carrying more current than it is suited to, a connection is loose or dirty, or the cable is damaged or too small for the duty. Running a high-current carbon through a torch rated lower is a common cause and it overheats the head and the air valve.

    Stop work and let it cool, then check the carbon size against the current, make sure the cable lug and torch connections are clean and tight, and inspect the cable for damage. Follow the maker's rated current and duty guidance for your torch. A torch that keeps overheating should be checked or replaced rather than pushed on.

    How do I inspect a gouging torch before I use it?icon-minus-redicon-plus-red

    Before each job, check that the cable insulation and the air hose are undamaged, the connections at the power source and compressed air are clean and tight, and the head, jaws and air holes are free of spatter and blockages. Operate the air valve to confirm air flows freely, and make sure the head grips the carbon firmly.

    Damaged cables can cause air leaks, a poor arc or electrical faults, so do not use a torch with cut or exposed conductors. Disconnect the power source and the air before any adjustment or repair. Follow the manufacturer's instructions and your own risk assessment for inspection intervals.