    ESAB Air Fed Parts FAQs

    Filters, seals, hoses and spares for one maker's powered air welding helmets: what each type of part does and how to choose and look after it.

    Why check airflow before every shift, and what does a low-flow alarm mean?icon-minus-redicon-plus-red

    A powered unit only protects if it provides enough filtered air to the head top. The HSE says maintenance of powered respirators includes checking the battery charge and the flow rate, and makers describe a simple flow indicator test before use. If the flow is below the minimum, do not use the unit until it has been examined and repaired.

    If an alarm sounds while you are working, leave the work area and find the cause. A blocked filter, a flat battery or a leaking hose or seal are common reasons. Follow your own manual.

    How should I clean and store air-fed helmet parts?icon-minus-redicon-plus-red

    The HSE says RPE should be stored according to the manufacturer's instructions, and that leaving it in dirty areas can contaminate the inside and deteriorate it through dirt, solvents and sunlight. HSE guidance adds that cleaning products other than those the maker recommends may cause problems.

    In practice, clean parts as the manual describes, let them dry and keep them in a clean, dry place away from sunlight, heat and solvents. Keep spare filters in their sealed wrapping until needed.

    What checks and records should I keep for a reusable powered helmet?icon-minus-redicon-plus-red

    The HSE says RPE should be inspected thoroughly before each use and that, for reusable RPE, you should keep a record of regular examinations, maintenance, repairs and, where appropriate, testing. Checks usually include the seals, hose, helmet shell, filters, battery and airflow.

    What counts as an adequate schedule depends on the equipment and the maker's instructions. HSE guidance explains who should carry out maintenance: trained, competent people. Report anything damaged and take it out of use until it is put right.

    Does a particle filter protect against welding gases?icon-minus-redicon-plus-red

    No. HSE guidance says FFP3 disposable masks and P3 particle filters do not protect against welding gases, and the same applies to a particle filter on a powered unit. Gas and combination filters exist, and powered units can be used with particle, gas or combined filters, depending on the unit.

    If your work produces gases or vapours as well as fume, check the risk assessment and the maker's manual to see which filter is required, and fit only the type named for your unit.