Practical answers on choosing, setting up and looking after a carbon arc gouging torch that runs on compressed air.
What does the amp rating on a gouging torch mean, and how do I match it to my job?

The rating is the highest welding current the torch is designed to carry. You need a torch rated at or above the highest current you will run, and that current is set by the carbon size you use. As a guide, hand gouging typically runs from roughly 275 A on a 6.4 mm carbon up to roughly 550 A on a 13 mm carbon, so a larger carbon needs a higher-rated torch.
Running a high-current carbon through an under-rated torch overheats the head and the air valve. Check the data plate or manual for the torch rating, and make sure your power source and cable can also supply the current you need.
How do I choose between a medium-duty and a heavy-duty gouging torch?

Think about the current and the length of the job. A lighter, more compact torch suits smaller carbons, shorter runs and general cleaning or repair work. A heavier-duty torch is built for larger carbons and higher currents, such as defect removal in foundries or long back-gouging runs on thick plate.
Heavier torches usually carry more cable and weigh more, so consider operator fatigue as well as rating. Buy to the highest current you expect to use, not the average, and check the maker's manual for the carbon sizes the torch is designed to hold. Our team can help you choose if you are unsure.
Why is my torch head or cable getting hot?

Heat usually means the torch is carrying more current than it is suited to, a connection is loose or dirty, or the cable is damaged or too small for the duty. Running a high-current carbon through a torch rated lower is a common cause and it overheats the head and the air valve.
Stop work and let it cool, then check the carbon size against the current, make sure the cable lug and torch connections are clean and tight, and inspect the cable for damage. Follow the maker's rated current and duty guidance for your torch. A torch that keeps overheating should be checked or replaced rather than pushed on.
How do I inspect a gouging torch before I use it?

Before each job, check that the cable insulation and the air hose are undamaged, the connections at the power source and compressed air are clean and tight, and the head, jaws and air holes are free of spatter and blockages. Operate the air valve to confirm air flows freely, and make sure the head grips the carbon firmly.
Damaged cables can cause air leaks, a poor arc or electrical faults, so do not use a torch with cut or exposed conductors. Disconnect the power source and the air before any adjustment or repair. Follow the manufacturer's instructions and your own risk assessment for inspection intervals.