    Standard Earth Clamps FAQs

    Practical answers about spring-loaded crocodile and screw-type earth clamps, and getting a reliable return connection.

    Why does a loose earth clamp cause problems?icon-minus-redicon-plus-red

    A poor or loose connection has higher electrical resistance, and that turns welding current into heat at the contact. Welding machine maker manuals warn that loose connections cause overheating, and that damaged cables or worn connections can create hot spots and a fire risk.

    You may notice an unstable arc, poor weld quality, sparking where the clamp touches the work, or a clamp and lead that become too hot to touch. If you see any of these, stop, check that the clamp is tight on clean metal and inspect the clamp and lead for damage before continuing.

    How should I prepare the spot where I clamp?icon-minus-redicon-plus-red

    Clamp onto clean, bare metal as close to the weld as practical. Maker manuals say the work clamp must be tightly connected to clean base metal, and recommend removing paint, rust and similar coatings where needed to get a good connection.

    A quick scrape or grind at the clamp position is usually enough. Avoid clamping onto thin or loose parts that could move, and check that the clamp jaws bite on the work and not just on a scale or coating. Re-check the connection if it has been knocked or the work has been moved.

    What does the amp rating on a clamp tell me?icon-minus-redicon-plus-red

    The rating shows the current the maker designed the clamp to carry. Clamps for welding current return are covered by a published standard for return clamps, and the rating on a clamp is based on the maker's testing. It is the figure to compare with the current you actually weld at, remembering that a heavier duty cycle means more heating.

    Choose a clamp with a rating comfortably above the current and duty cycle you will use, and check the data on the clamp or in the maker's information. An undersized clamp is a common reason for overheating.

    When do I replace an earth clamp?icon-minus-redicon-plus-red

    Replace a clamp that has a weak or broken spring, jaws that no longer meet squarely, a bent or cracked body, burn marks, a loose cable connection that cannot be tightened, or damaged insulation on the handles or lead. Maker manuals advise checking and tightening connections regularly and replacing damaged parts.