    Jackson WH25 with R60 System Parts FAQs

    Spare parts for a powered air-purifying welding helmet system: how to choose them, when they wear out and how to look after them.

    Does a powered air welding helmet protect against welding gases?icon-minus-redicon-plus-red

    Not necessarily. Particle (P3) filters protect against the particles in welding fume, but these particulate filters will not protect against the gases in the fume, and a particle filter must never be relied on against gases. If gases are a concern, your risk assessment must decide whether a different filter type or a supplied-air system is needed.

    For arc welders, a powered or supplied-air respirator that combines respiratory, eye and face protection, with an assigned protection factor (APF) of at least 20, is the best option. Check the manual and data plate for how your system is classed and which filters it is approved with.

    How do I know when the filters need replacing?icon-minus-redicon-plus-red

    Filters have a limited capacity and can become clogged, so they should be changed when necessary and as the maker instructs. Typical signs are a filter or low-airflow alarm or indicator that appears with a freshly charged battery, noticeably weaker airflow, or visible damage or heavy loading. Heavy use in spark-heavy or dusty conditions generally means more frequent changes.

    On a unit with more than one filter, fit identical filters and change them all together. A maker's manual for a related respirator also says the particle filter must not be cleaned in any way, so do not wash, tap or blow out filters. The change interval depends on the maker and your working conditions, so follow the manual and your risk assessment.

    What should I do if the low-airflow or low-battery alarm sounds?icon-minus-redicon-plus-red

    Treat it as a warning that you are no longer getting the airflow the system needs. Never keep working if the fan stops or the flow rate falls: leave the work area immediately, then look for the cause. Common causes are a flat battery, a clogged filter, or a kinked, split or disconnected hose or air duct.

    Recharge or replace the battery, or change the filters, in clean air before going back. If the alarm does not clear, take the unit out of use and refer to the manual or the maker. Do not use the equipment if it is dirty, damaged, incomplete or not providing enough air.

    What do the TH classes on a powered helmet mean, and do I need a face-fit test?icon-minus-redicon-plus-red

    Helmet-type powered respirators are rated by protection class. A higher class gives a higher rated reduction in what you breathe in, and for arc welders an APF of at least 20 is the best option. Check the data plate and manual for the class your system holds with its filters.

    Unlike tight-fitting masks, loose-fitting helmets and hoods do not need a face-fit test, and a loose-fitting device suits workers who cannot be clean-shaven. Other head-worn protection can interfere with RPE, so make sure anything you wear with the helmet is compatible.