Why do electrodes need to be kept dry at the point of use?

The coating on a low-hydrogen electrode can pick up moisture from the air, and that moisture is the main source of hydrogen in the weld. Hydrogen in the weld area is one of the three conditions that can lead to hydrogen cracking, alongside a susceptible microstructure and tensile stress.
Keeping electrodes dry between the sealed pack or drying oven and the arc is therefore part of controlling that risk. A portable oven does this at the work position, so electrodes are not left in open air while you weld.
What goes wrong if I weld with electrodes that have absorbed moisture?

Moisture in the coating adds hydrogen to the weld. Hydrogen cracking is also called cold or delayed cracking, because it can appear some time after welding, at or near room temperature, so a weld that looks fine at the time can still fail later.
In practice, damp electrodes are more likely to give an unstable, spattery arc and porosity as well. If electrodes have been left out for longer than the maker allows, treat them as suspect and follow the maker's instructions for re-drying or replacing them rather than hoping for the best.
What should I put in the oven, and when?

Load electrodes that are already dry: straight from a freshly opened sealed pack or from a drying oven, as the maker recommends. Low-hydrogen electrodes should be baked as the manufacturer recommends or taken from special packaging immediately before use.
Keep the lid closed except when you take electrodes out, and keep the electrode type and size labelled so they are not muddled. Do not load electrodes that have been left out in the open for a long time or look damaged; follow the maker's instructions on those.
Can a portable oven rescue damp electrodes?

Usually not on its own. The guidance varies: some portable ovens only hold a mild temperature, which is aimed at keeping dry electrodes dry rather than driving out moisture. Re-drying normally needs the temperature and time set by the electrode maker, which is often well above the holding temperature.
Check your oven's manual to see what it is designed to do. If electrodes are damp, follow the maker's re-drying instructions in a suitable oven, or replace them. Electrodes whose coating has become fragile or is flaking should be discarded.