Machine TIG Torches FAQs
Answers to common questions about machine (mechanised) TIG torches fitted to carriages, positioners and automated welding heads.
When should I choose a water-cooled machine TIG torch instead of a gas-cooled one?

Gas-cooled torches suit lower currents. They are compact and light and need no extra cooling equipment. Water-cooled torches are generally chosen for consistently high current, long production runs, thick material and automated work, because active cooling helps the torch and its wear parts last longer and keeps weld quality steadier.
Because a machine torch often welds for long periods without a break, many users lean towards water cooling as the current rises. Check the torch's rated current, shielding gas and duty cycle against your actual welding current and arc-on time rather than choosing on size alone.
What is the difference between a machine torch and a hand-held TIG torch?

A machine torch is built to be clamped in a carriage, positioner, slide or robot arm instead of being held by a welder. It normally has a straight, rigid barrel-style body that suits a clamp, and no handle or trigger switch, because the welding machine or controller starts and stops the arc.
The standard for arc welding torches covers mechanically guided and liquid-cooled types as well as manual ones, so machine torches are a recognised type in their own right. Check the body diameter, connections and cooling type against your mounting and power source.
Do I need eye protection and screens around an automated TIG station?

Yes. The arc gives off ultraviolet, visible and infrared radiation whether it is started by hand or by a controller. HSE describes arc eye as an injury to the front of the eye after exposure to welding radiation, usually becoming painful and red a few hours later. UV can also cause sunburn-like reddening of skin.
Face and eye protection with a suitable filter, covered skin, and non-reflective screens for anyone nearby are the usual controls. Anyone setting up or watching the torch while the arc is on needs the same protection as a welder. Follow your risk assessment.
Does mechanised TIG welding still produce fume I need to control?

Yes. Automation does not remove welding fume, and HSE states that both acute and chronic health risks are associated with it. Fume is best controlled at source, for example with local exhaust ventilation positioned close to the weld, rather than relying on respiratory protection alone.
What suits your set-up depends on the material, the welding time and the enclosure, so it needs to come from your risk assessment (COSHH). Check any extraction is positioned so it does not pull shielding gas away from the weld pool.