When should I choose a water-cooled machine TIG torch instead of a gas-cooled one?

Gas-cooled torches suit lower currents. They are compact and light and need no extra cooling equipment. Water-cooled torches are generally chosen for consistently high current, long production runs, thick material and automated work, because active cooling helps the torch and its wear parts last longer and keeps weld quality steadier.
Because a machine torch often welds for long periods without a break, many users lean towards water cooling as the current rises. Check the torch's rated current, shielding gas and duty cycle against your actual welding current and arc-on time rather than choosing on size alone.
What is the difference between a machine torch and a hand-held TIG torch?

A machine torch is built to be clamped in a carriage, positioner, slide or robot arm instead of being held by a welder. It normally has a straight, rigid barrel-style body that suits a clamp, and no handle or trigger switch, because the welding machine or controller starts and stops the arc.
The standard for arc welding torches covers mechanically guided and liquid-cooled types as well as manual ones, so machine torches are a recognised type in their own right. Check the body diameter, connections and cooling type against your mounting and power source.
What does arc voltage control do on a machine TIG torch?

Arc voltage rises and falls with the distance between the tungsten and the work. An arc voltage control compares the measured voltage with a preset value and drives a slide to raise or lower the torch, so the arc length stays steady along the joint.
That helps keep penetration and heat input consistent on long welds, and it can also compensate as the tungsten erodes. It is normally an add-on unit used with a machine torch, so check that the torch body can be mounted on the slide you plan to use.
Does mechanised TIG welding still produce fume I need to control?

Yes. Automation does not remove welding fume, and HSE states that both acute and chronic health risks are associated with it. Fume is best controlled at source, for example with local exhaust ventilation positioned close to the weld, rather than relying on respiratory protection alone.
What suits your set-up depends on the material, the welding time and the enclosure, so it needs to come from your risk assessment (COSHH). Check any extraction is positioned so it does not pull shielding gas away from the weld pool.