Gas Fittings FAQs
Union nuts, tails, couplers, adaptors and clips for gas welding hose: how to choose them and fit them safely.
How do I work out which thread and size of fitting I need?

Start with the connection you are joining to, such as the regulator outlet or the blowpipe inlet, and read the thread size and hand (left or right) marked on it or given in the maker's data. Common gas welding connections use parallel threads in sizes such as 1/4 inch and 3/8 inch, with a left-hand thread for fuel gas and a right-hand thread for oxygen. The nut size is separate from the bore of the hose that goes on the tail.
Standards for hose connections set the dimensions of the union, nut and tail so that parts made to them fit together, but makers differ in detail. If you are unsure, check the existing part against the data plate or manual, or ask our team to help you identify it.
How do I match a hose tail to my hose?

The tail has to suit the bore (inside diameter) of the hose, and the nut has to suit the thread of the connection it screws onto. These are two different sizes, which is why you will see tails sold as, for example, a particular bore for a particular nut size. Measure or check the marking on the hose, rather than guessing from the outside diameter.
The standard for hose connections covers the union, nut and other connection parts but not the design of the tail that goes inside the hose; hose assemblies are covered by a separate standard. A tail that is too loose or too tight in the hose can leak or damage the hose, so choose one made for gas welding hose of your bore.
How do I fit a hose tail and ferrule or clip properly?

Cut the hose square and clean, push it fully onto the tail, then secure it with a ferrule or clip of the correct size for the hose, using the crimping tool or pliers made for that clip. Choose a ferrule that matches the outside diameter of the hose, because a ferrule that is too large will not grip properly. A badly fitted fitting can leak, which can lead to fire or flashback.
After fitting, check that the hose cannot be pulled off the tail by hand and leak test the joint with the hose pressurised. Follow the maker's instructions for the clip or ferrule you are using.
Can I fit quick-connect couplings in a gas welding hose?

Yes, if they are designed for the job. There is a standard for quick-action couplings with shut-off valves for gas welding, cutting and allied processes, which covers couplings placed between the regulator and the torch and used with gas welding hose or threaded unions. Use only couplings made for the gas in question, and do not use garden or air line type connectors on welding gas hose.
Oxygen and fuel gas couplings must not be interchangeable. Check that the coupling fits your thread and bore, and look at the maker's instructions for the working pressure and for how often to check it.