Straight answers to the questions people ask most when choosing, fitting and looking after welding cable connectors.
What types of welding cable connector are there?

The main types are plug-in connectors, with male and female halves that join cables to each other or to the machine, and lugs, which are fitted to the cable end for bolting to a terminal. There are also panel-mounted plugs and sockets for fitting into equipment, in-line joiners for lengthening cable, branch connectors for sharing a supply, power adaptors that join different sizes, and small multi-pin control plugs.
Choose according to what you are connecting and the cable size and current.
How do I choose the right size of connector?

A connector must match the cross-section of the cable it is fitted to and the socket or plug it connects to, and it must be rated for the current. Connectors are normally made for a range of cable sizes, and the size is marked on them or given by the maker.
If the cable is too small or large for the connector, you get a poor grip and a hot joint. Check the cable size, the machine's socket size and the current before you buy. An adaptor can join different sizes, but the weakest part limits the capacity.
How do I fit a connector to a welding cable?

Cut the cable square, strip back the right length of insulation without cutting any strands, and insert the conductor fully into the connector. Then secure it as the connector is designed: with a grub screw, a crimp made with the correct tool or another method given by the maker.
After fitting, give the cable a firm tug to check the grip, make sure no strands stick out and that any insulating cover is fully in place. A poor joint overheats, so take care.
Which half goes on the machine and which on the cable?

On many machines the output sockets are female, with the live metal recessed and shrouded, and the cable carries the male plug. This helps stop live metal being exposed when a plug is pulled out. It is a common arrangement rather than a rule, so do not assume it for your own equipment.
Check the data plate and manual for your machine to see how its connections are arranged, and make sure the end of a live cable cannot touch anything it should not. Always switch off and isolate the machine before changing or inspecting connections.
Why is my connector getting hot?

Heat at a connector means high resistance. The causes are a loose or partly inserted plug, a connector that is too small for the current, dirty, burnt or pitted contacts, a poor crimp or loose screw on the cable, or a damaged connector.
Stop welding and let it cool. Check that it is the right size, fully inserted and, if it is a twist-lock type, properly turned. Clean the contacts, check the cable joint, and replace the connector if it is discoloured or damaged. A hot connector also wastes power and may spoil the weld.
Can I join two lengths of cable together to make it longer?

Yes, with a correct in-line joiner or male and female connectors, but each join adds some resistance, and a longer cable has more voltage drop, which can weaken the arc. Use as few joins as possible and use a cable size suited to the length and current.
Keep the joins tight, clean and well insulated, and keep them off the wet floor and out of the way of traffic. If you regularly need more reach, a single longer cable is better than lots of short ones.
What is a branch or dual cable connector for?

These connectors join more than one cable to a single point. They are used to run two cables in parallel where a single cable would be too heavy or not rated for the current, or to split a supply between connections.
Follow the machine maker's guidance, because cables sharing a load must be matched in size and length and the connector must be rated for the total current. Do not improvise, as an unbalanced or undersized arrangement can overheat.