WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : J1905  

    Curv-O-Mark Contour Replacement Dial-Set Level
    J1905

    £10.85  EX VAT
    SSP Suggested Selling Price = £12.70  YOU SAVE £1.85

    The Dial-Set Level is an adjustable bubble protractor. This item covers 180° through two 90° quadrants and the bubble is cast in the aluminium dial for durability.

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure

    Related Items

    Contour Pipe Fit Up Tools FAQs

    Answers to common questions about precision pipe marking, centring, levelling and angle tools used by pipe fitters and pipe welders.

    Can magnetic fit-up tools cause arc blow?icon-minus-redicon-plus-red

    They can. Arc blow is the deflection of the welding arc by magnetic fields, and one recognised cause is residual magnetism left in the steel after magnets have been used for handling. If the arc wanders or will not stay where you aim it, suspect magnetised pipe.

    Often the only effective cure is to demagnetise the steel before welding, although positioning the current return so that you weld towards or away from the clamp, or using alternating current where the process allows, can also help. Magnetic levels and aligners are fine for setting up, but take them off before you strike an arc.

    Are the strong magnets in pipe levels and aligners a hazard?icon-minus-redicon-plus-red

    They can be. Strong magnets snap onto steel and onto each other with enough force to pinch or crush fingers, so guide them on and off steadily, keep your fingers clear of the gap and wear gloves with larger magnets. Keep them away from mechanical watches, bank cards and electronic equipment.

    Anyone with a pacemaker or similar implanted device should keep magnets away from it. Heart charity guidance is to keep anything with a magnetic field about six inches (15 cm) or more from the device, and to ask your doctor or pacing clinic if in doubt. Strong tool magnets may call for more distance, so check with the person's medical team and follow your own risk assessment.

    Why is the diameter I measure not the same as the size the pipe is sold by?icon-minus-redicon-plus-red

    Pipe is designated by a nominal size, which is a name for the size rather than a measurement. For smaller sizes the real outside diameter is different from the nominal figure, and only at larger sizes do the two match, so measure the outside of the pipe, or check the standard's size table, before choosing a tool. Tools are normally rated by the range of pipe sizes they fit, so look at the range on the tool.

    For a given nominal size the outside diameter is fixed and the schedule changes the wall thickness, and so the bore. A heavier wall therefore still fits the same marking or centring tool. Metric and inch designations differ, so check which one the tool uses.

    Will a slightly oval pipe affect my marking or centring tools?icon-minus-redicon-plus-red

    It can. Tools that locate on the outside of the pipe assume a round section, so pipe that is oval, dented or out of round can leave a small error in a marked line or in the centred position. Trade guidance on pipe fit-up notes that greater variation in diameter, wall thickness, ovality and straightness generally makes problems worse later during welding.

    Check the ends with a tape or calipers in two directions before you start, and try the tool at more than one position. Matching pipe ends, for example by turning one pipe against the other to the best fit, can reduce the problem. If a mark or alignment looks wrong, rotate the pipe and recheck before you cut or tack.

    Shop Similar Categories