SFE-25 / 50 HFE25 / 50 Spare Parts FAQs
Straight answers to the questions people ask most when choosing and fitting spares for an electrostatic fume filter unit.
How do I identify the right spare for my electrostatic filter unit?

Use the data plate on the unit for the model, serial number and electrical details, and note the year of manufacture. Makers change electrical and mechanical parts over a model's life, so older and newer units of the same name can need different parts.
Check the parts list in the manual, and if you cannot confirm a match, send our team a photo of the old part and the data plate before you buy.
How does an electrostatic filter work, in simple terms?

The fume first passes through a pre-filter that catches larger particles. It then goes through an ioniser, which gives the particles an electrical charge, and on to collector plates that attract and hold them. A final filter may catch what remains.
Because the collector plates hold the particles, on many units they can be cleaned and reused rather than thrown away. Check the manual for your own unit. The electrical parts, such as the transformer and the ioniser, are what make the system work.
How often should the collector cells be cleaned?

Follow the maker's guidance, which depends on how heavily the unit is used. Cells coated with deposits capture less, can arc or cause the unit to trip, and may produce an unpleasant smell.
Switch off and isolate the unit and follow the manual for how long to wait and how to make the high voltage parts safe before you open it. Use only the cleaning method the maker recommends, and make sure the cells are completely dry before they go back, because moisture can cause arcing.
Why does the unit make a crackling noise or trip out?

Crackling or tripping usually points to dirty or damp collector cells, a damaged or misaligned part inside the cell, a failing insulator, or deposits bridging the high voltage parts. Moisture is a common cause after cleaning.
Switch off and isolate before you investigate. Clean and dry the cells, check the insulators for cracks or tracking marks, and replace any that are damaged.