Practical answers on the welding lead set and argon flowmeter that go with a small inverter welder.
What is in a basic MMA welding lead set and what is each part for?

A typical set has a return lead with a work clamp, and an electrode lead with an electrode holder. The holder grips the stick electrode and carries current to it. The clamp attaches to the workpiece, or to the bench it sits on, to complete the circuit back to the welder. The return lead is often wrongly called the earth lead.
Both leads normally end in plugs that fit the sockets on the front of the welder. Check that the plug type, cable size and current rating suit your welder's data plate and the electrodes you plan to use.
Where should I fit the work clamp, and does it really matter?

Yes, it matters. The return clamp should connect directly to the workpiece, or to the bench it rests on, as close to the weld as practicable. Do not use rails, pipes or frames as part of the circuit unless they are part of the workpiece itself.
Attach it to bright metal and remove rust or primer at the contact point, because a poor connection can overheat and arc. Faulty return paths can also let current stray through other conductors, so keep the return lead and clamp insulation in good condition.
How do I know whether a lead set suits my welder?

Start with the welder's data plate and manual, which give the maximum output current and the duty cycle. Cable diameter is chosen mainly by the welding current: higher current and a higher duty cycle need a larger cable to avoid overheating, and long runs may need a larger cable still to limit voltage drop.
The cable should also be insulated and its connectors and holder should be suitable for the current. Published sizing charts differ in their assumptions, so treat the welder maker's guidance as the deciding source. If in doubt, a larger cable is the safer choice than a smaller one.
How often should I check the leads and electrode holder, and what am I looking for?

Check them before each use. The welder should check cables, holder and couplings daily for damage and report defects. Look for cracked, cut or crushed insulation, exposed copper, a cracked or loose holder, worn jaws, loose plugs and a clamp that no longer grips firmly.
Wear is often worst where the cable flexes, such as close to the holder. Do not use damaged equipment: have it repaired or replaced and report it. Employers should also have a programme of regular checks for welding sets, and formal inspection and testing by a competent person may be needed at intervals suited to the equipment and how it is used.
Why does my electrode holder or work clamp get hot?

Heat at a connection usually points to resistance in the circuit. Poor connections between electrode, holder and cable cause resistance heating that can overheat the holder, and clamps need a good contact to the workpiece to avoid overheating and arcing.
Common causes are a clamp on rusty or painted metal, a worn clamp, a loose plug in the welder socket, a loose cable connection inside the holder, or a cable that is too small or damaged. Stop welding and let it cool before you investigate. Clean the contact point, check the plugs are fully seated, and replace any part that keeps overheating.
Which way round do I connect the leads - electrode positive or negative?

It depends on the electrode, not on the lead set. The electrode flux coating is the overruling factor, and the maker's polarity instructions on the electrode pack or data sheet decide it. Some electrodes are DC only, while others can run on either AC or DC.
Polarity is changed by swapping which front socket each lead plugs into, always with the welder switched off. Electrode positive generally gives deeper penetration and electrode negative shallower penetration, but follow the electrode maker's instructions and your welding procedure rather than a general rule.