WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE

Invertec 170 S Options

Invertec 170 S Options FAQs

Practical answers on welding lead sets and argon flow control for a small inverter welder.

What is in a welding lead set and what does each part do?icon-minus-redicon-plus-red

A typical lead set for stick welding has a work (return) cable with a clamp, and an electrode cable with an insulated electrode holder. The work clamp completes the circuit back to the welder through the workpiece, while the holder grips the electrode and carries current to the arc.

Both cables must be insulated and the cables and connectors must be adequate for the welding current, so the set should be matched to the welder's maximum output and its output sockets. Check the data plate and manual for the connector type and current rating before choosing a set.

Where should I attach the work clamp?icon-minus-redicon-plus-red

Connect it directly to the workpiece, as close to the weld as practical, or to a bench that holds the workpiece. Remove rust, paint, primer or scale at the contact point so the clamp grips clean, bright metal. A poor connection can overheat and arc, and it makes the machine work harder for the same weld.

Keep the return path as direct as you can and make sure the clamp grips firmly and is rated for the current. If the clamp or its jaws are loose, corroded or burnt, repair or replace them rather than continuing with a weak connection.

How often should I check leads and the electrode holder for damage?icon-minus-redicon-plus-red

Check them before use. The welder should inspect the cables, holder and couplings daily and report defects, and connections should be clean and tight each time you reconnect. Your risk assessment may call for more formal checks at set intervals.

Look for cuts, cracks or burns in the insulation, exposed copper, loose or hot connections and a cracked holder body. Electrode holders should be insulated overall so bare metal cannot be touched by accident, and the holder should be isolated when you change the electrode. Do not weld with a damaged lead or holder because of the risk of electric shock and fire.

How do I check for gas leaks around the flowmeter and hose?icon-minus-redicon-plus-red

With the gas supply on and the torch closed, check the cylinder connection, flowmeter joints and hose connections using an approved leak-detection solution, and look for bubbles. A pressure-drop check can also be used: close the supply and watch for the gauge or ball moving. Do not use household washing-up liquid on gas equipment. Never oil or grease the fittings.

If you lose cylinder contents faster than expected or the flow reading wanders, suspect a leak or a worn seal. Do not work with damaged or leaking equipment; have it inspected or replaced. Leaked argon is heavier than air and can collect in low or enclosed spaces, so keep the area ventilated.

Will the flowmeter fit my cylinder and my welder?icon-minus-redicon-plus-red

Check three things before ordering: the inlet connection must be designed for the gas and suit the regulator or outlet it screws onto, the outlet fitting must match your gas hose, and the scale and pressure rating must suit the gas and your set-up. Thread forms differ between countries and gases, so do not force a fitting that does not screw on easily.

Before fitting, look over the threads and sealing faces for damage, dirt, oil or grease, and do not use the equipment if any is present. If you cannot confirm the match from the manual or the markings on the old part, ask our team to help you check before you fit anything.

How do I choose the flow range and read the scale?icon-minus-redicon-plus-red

Pick a meter whose scale covers the flow you normally need, with your usual setting in the middle of the range rather than at either end. Check that the scale is intended for argon, as scales are calibrated for particular gases.

Mount the meter upright, because the flow tube only reads accurately when vertical. Where you read the floating ball differs between designs, the centre of the ball being common, so follow the markings on the tube or the instructions.