    Lincoln Welding Kit - 5m Workpiece Cable, Clamp & E/Holder - 200A
    KIT-140A-25-5M

    £148.82  EX VAT
    SSP Suggested Selling Price = £165.29  YOU SAVE £16.47
     Buy in 3 easy interest free payments of £49.61† with

    5m Workpiece Cable, Clamp & Electrode Holder - 200A.

    Invertec 170 S Options FAQs

    Practical answers on welding lead sets and argon flow control for a small inverter welder.

    Where should I attach the work clamp?icon-minus-redicon-plus-red

    Connect it directly to the workpiece, as close to the weld as practical, or to a bench that holds the workpiece. Remove rust, paint, primer or scale at the contact point so the clamp grips clean, bright metal. A poor connection can overheat and arc, and it makes the machine work harder for the same weld.

    Keep the return path as direct as you can and make sure the clamp grips firmly and is rated for the current. If the clamp or its jaws are loose, corroded or burnt, repair or replace them rather than continuing with a weak connection.

    How often should I check leads and the electrode holder for damage?icon-minus-redicon-plus-red

    Check them before use. The welder should inspect the cables, holder and couplings daily and report defects, and connections should be clean and tight each time you reconnect. Your risk assessment may call for more formal checks at set intervals.

    Look for cuts, cracks or burns in the insulation, exposed copper, loose or hot connections and a cracked holder body. Electrode holders should be insulated overall so bare metal cannot be touched by accident, and the holder should be isolated when you change the electrode. Do not weld with a damaged lead or holder because of the risk of electric shock and fire.

    How do I check for gas leaks around the flowmeter and hose?icon-minus-redicon-plus-red

    With the gas supply on and the torch closed, check the cylinder connection, flowmeter joints and hose connections using an approved leak-detection solution, and look for bubbles. A pressure-drop check can also be used: close the supply and watch for the gauge or ball moving. Do not use household washing-up liquid on gas equipment. Never oil or grease the fittings.

    If you lose cylinder contents faster than expected or the flow reading wanders, suspect a leak or a worn seal. Do not work with damaged or leaking equipment; have it inspected or replaced. Leaked argon is heavier than air and can collect in low or enclosed spaces, so keep the area ventilated.

    How do I choose the flow range and read the scale?icon-minus-redicon-plus-red

    Pick a meter whose scale covers the flow you normally need, with your usual setting in the middle of the range rather than at either end. Check that the scale is intended for argon, as scales are calibrated for particular gases.

    Mount the meter upright, because the flow tube only reads accurately when vertical. Where you read the floating ball differs between designs, the centre of the ball being common, so follow the markings on the tube or the instructions.