    Rapid Ref : 0328400100  

    Thermal Relay NTR-1.4-2.0 A 400v 3ph 50 /60Hz
    0328400100

    £95.65  EX VAT
     Buy in 3 easy interest free payments of £31.88† with

    SFE-25 / 50 HFE25 / 50 Spare Parts FAQs

    Straight answers to the questions people ask most when choosing and fitting spares for an electrostatic fume filter unit.

    How do I identify the right spare for my electrostatic filter unit?icon-minus-redicon-plus-red

    Use the data plate on the unit for the model, serial number and electrical details, and note the year of manufacture. Makers change electrical and mechanical parts over a model's life, so older and newer units of the same name can need different parts.

    Check the parts list in the manual, and if you cannot confirm a match, send our team a photo of the old part and the data plate before you buy.

    How often should the collector cells be cleaned?icon-minus-redicon-plus-red

    Follow the maker's guidance, which depends on how heavily the unit is used. Cells coated with deposits capture less, can arc or cause the unit to trip, and may produce an unpleasant smell.

    Switch off and isolate the unit and follow the manual for how long to wait and how to make the high voltage parts safe before you open it. Use only the cleaning method the maker recommends, and make sure the cells are completely dry before they go back, because moisture can cause arcing.

    Why does the unit make a crackling noise or trip out?icon-minus-redicon-plus-red

    Crackling or tripping usually points to dirty or damp collector cells, a damaged or misaligned part inside the cell, a failing insulator, or deposits bridging the high voltage parts. Moisture is a common cause after cleaning.

    Switch off and isolate before you investigate. Clean and dry the cells, check the insulators for cracks or tracking marks, and replace any that are damaged.

    Which parts wear mechanically?icon-minus-redicon-plus-red

    The fan belts, the motor bearings, the door seals and the fixings are the main ones. A worn belt slips, squeals and reduces airflow, and a cracked belt will fail without warning.

    Check the belt tension and condition at each service and replace the belts as a matching set where the unit has more than one. Replace the door seals if they harden or crack, so air does not bypass the filters.