    Straight answers to the questions people ask most when choosing and fitting spares for an electrostatic fume filter unit.

    When do the pre-filters and final filters need replacing?icon-minus-redicon-plus-red

    Replace them when they are visibly loaded, damaged or when airflow has dropped, or when the maker's schedule says so. The pre-filter protects the rest of the unit, so letting it clog hurts the whole system.

    The interval depends on the amount of fume, the type of work and how the unit runs, so inspect them regularly rather than waiting for a fixed time.

    Why does the unit make a crackling noise or trip out?icon-minus-redicon-plus-red

    Crackling or tripping usually points to dirty or damp collector cells, a damaged or misaligned part inside the cell, a failing insulator, or deposits bridging the high voltage parts. Moisture is a common cause after cleaning.

    Switch off and isolate before you investigate. Clean and dry the cells, check the insulators for cracks or tracking marks, and replace any that are damaged.

    What do the insulators do and when should they be replaced?icon-minus-redicon-plus-red

    Insulators hold the high voltage parts away from the metalwork. If they are dirty, cracked or marked by tracking, the electricity can leak or arc where it should not.

    Inspect them whenever you clean the cells and replace any that are cracked, burnt or heavily marked. Use the exact replacement, because the fit and the electrical properties matter.

    Which parts wear mechanically?icon-minus-redicon-plus-red

    The fan belts, the motor bearings, the door seals and the fixings are the main ones. A worn belt slips, squeals and reduces airflow, and a cracked belt will fail without warning.

    Check the belt tension and condition at each service and replace the belts as a matching set where the unit has more than one. Replace the door seals if they harden or crack, so air does not bypass the filters.