    Rapid Ref : AVC-OSC114-100  

    Orbital Service AVC-OSC Upgrade Kit for OWH114
    AVC-OSC114-100

    £6629.82  EX VAT
     Buy in 3 easy interest free payments of £2209.94† with
    AVC/OSC upgrade kit for OWH-114 composed of: AVC/OSC kit, plastic insulator and TIG-torch clamp.

    Related Items

    Open Weld Heads FAQs

    Answers to common questions about choosing, setting up and looking after open orbital TIG weld heads and their accessories.

    What is an open weld head and when would I choose one over an enclosed head?icon-minus-redicon-plus-red

    An open weld head carries the TIG torch round the tube but does not seal the joint inside a gas chamber. That leaves the joint visible and easier to reach, and it allows extra wire to be fed into the pool, which helps on thicker walls and multi-pass joints. The torch can also be positioned with a controlled arc gap, which suits tube that is not perfectly round.

    Enclosed heads surround the joint with shielding gas and are generally preferred for very clean, high purity tube work. Open heads usually cover a wider range of sizes up to larger diameters. Check the tube outside diameter, wall thickness and your weld procedure before choosing, and our team can help you match a head to the job.

    Why does an open weld head need arc voltage control, and what does it do?icon-minus-redicon-plus-red

    On an open head the distance between the electrode tip and the weld pool is not fixed mechanically. If the tube is slightly out of round, the arc gap changes as the torch travels round it, and that changes heat input and penetration. Arc voltage rises and falls with arc length, so an arc voltage control unit reads the voltage and moves the torch up or down to hold the gap steady.

    That is why open heads are often fitted with it, especially on thicker or less perfectly round tube. Settings such as starting gap and sensitivity depend on the equipment and your procedure, so follow the maker's manual.

    Do I need to purge the inside of the tube when using an open weld head?icon-minus-redicon-plus-red

    Yes, in most stainless steel and other corrosion-resistant work. Welding without protecting the inside of the joint lets oxygen react with the hot root, causing heat tint that reduces corrosion resistance. Orbital welds are often said to succeed or fail on the quality of the purge, so take it seriously.

    Purge before welding until the oxygen content is as low as your procedure requires (an oxygen analyser is the reliable way to check), and keep the back purge running until the root and hot pass are finished. Purge gas choice and flow depend on the material and joint, so check your procedure.

    When do I need a cold wire feeder with an open weld head?icon-minus-redicon-plus-red

    Thin-walled tube is often welded without any added wire, but thicker walls, or materials that are harder to control, usually need extra filler material. Because the arc is open, a cold wire feeder can feed wire into the pool, which allows multi-pass welds in thicker sections.

    Wire diameter, spool size, feed speed and joint preparation all depend on the head, the wire feeder and your procedure. A wire holder that suits the torch and a clean, correctly aimed wire are important, as wire placement strongly affects the weld. Our team can help you check that the wire feeder and head work together.