Turntable FAQs
Practical answers on choosing, setting up and looking after a turntable system for automated TIG welding of small round parts and tubes.
How should I choose and prepare the tungsten electrode?

Pick the electrode type and diameter to suit the welding current and the material. Lanthanated and ceriated types are widely used for DC work on stainless steel and have largely replaced thoriated electrodes, which contain a mildly radioactive material and need extra care when grinding.
Grind the point so the grinding marks run along the length of the electrode, not across it, as electrode and grinder makers advise. Use a grinder kept for tungsten only to avoid contamination. A sharper point tends to give a wider, shallower bead, while a blunter point tends to give deeper penetration.
Keep the tip shape the same from weld to weld, as automatic welding relies on repeatability. Follow the maker's guidance for your torch and the weld procedure for your job.
How accurate does the joint fit-up need to be for automatic TIG welding of small tubes?

Very accurate. Tube ends should be square, clean and closely matched, and free of burrs. A gap, burr or contamination at the joint causes defects that changing the welding parameters will not cure.
That is why a good cut or facing operation before welding matters as much as the welding settings. Where no filler wire is added, as is common on thin-walled small tubes, the joint has to do all the work, so tight fit-up is even more important.
The acceptable gap and misalignment depend on the wall thickness, the material and your welding procedure or customer specification, so check those rather than relying on a general figure.
Do I need to purge the inside of the tube, and how?

For stainless steel and similar materials, yes. Filling the bore with inert gas before and during welding helps prevent oxidation, porosity and loss of corrosion resistance on the inside of the weld.
Inflatable purge plugs are generally recommended over cardboard discs or improvised seals, because they seal the bore reliably. Argon is the usual gas, and reactive metals such as titanium need a higher purity grade. Do not assume the purge is complete just because a certain time has passed: an oxygen monitor is the reliable way to confirm that oxygen is low enough.
The oxygen level you need depends on the material and the specification you are working to, so check your welding procedure.
What sort of work is a turntable system used for?

A turntable system is used where a small round part or tube needs a circumferential TIG weld that is the same every time. Typical jobs include joining short tube sections, welding fittings onto tube ends and similar round-section work in stainless steel and other TIG-weldable materials.
The workpiece is clamped, rotated at a set speed and welded by a torch held in a fixed position, so the weld is controlled by the settings rather than by a welder's hand. Supports and holders let you position the torch and adjust it for the joint.
The diameter range is set by the system, so check the part size against the maker's stated range.