    CK300 Torch Parts FAQs

    Practical answers on choosing, fitting and looking after the torch body, hoses, power cable and back cap for a large water-cooled TIG torch.

    Why does the power cable inside a water-cooled hose fail, and which way should the coolant flow?icon-minus-redicon-plus-red

    In many water-cooled torches the power cable runs inside the coolant return hose, so coolant passes along it on its way back to the cooler. A torch maker's troubleshooting guide says that when water-cooled leads wear out quickly you should verify the coolant flow direction: the return flow must be on the power cable lead. Another maker's manual warns that if the coolant connections are crossed the torch may overheat.

    Constant flexing can also wear the cable. A cable that runs hot, feels stiff or leaks at the fitting should be checked and normally replaced rather than patched.

    What are the signs that a hose or power cable needs replacing?icon-minus-redicon-plus-red

    Look for cracking, ballooning or bubbling, thinning walls, cuts, scuffed outer covers, stiffness and drips at the fittings. Welding-equipment makers' manuals say hose packs should be undamaged and securely connected, damaged parts should be replaced immediately, and a leaking hose pack should be replaced because a leak can cause high-frequency flashover.

    A cable that gets hot, a hose that kinks easily or coolant that returns weakly can also point to a worn or partly blocked assembly. Do not tape a leaking hose; replace the whole hose or cable assembly.

    How do I work out which torch body, hose or cable I need?icon-minus-redicon-plus-red

    Start with the data plate on the torch and the manual, which give the torch type and cooling method. Then compare the old part: note any markings, the fitting type and thread, the length and whether it is a water hose, a power cable that also returns coolant, or a gas hose.

    Take clear photos of the connectors at both ends. Fittings and threads differ between torch families, so never assume a part from another range will fit. If in doubt, our team can help you match the part to your torch.

    What coolant should I use in the cooler?icon-minus-redicon-plus-red

    Use the coolant specified by the cooler and torch makers. Advice differs: one trade article says to use only distilled water or an approved welding coolant and never city water, anti-freeze or rust inhibitors, while a torch maker's manual says not to use deionised or demineralised water. Tap water is widely discouraged because it can leave deposits, cause corrosion and clog the torch.

    Do not mix coolant types or add other additives unless the manual says so, and drain and refill at the interval it gives. Dirty or degraded coolant is a common cause of clogged torch fittings. If the manuals for the cooler and the torch disagree, ask the makers which coolant to use.