    OK Autrod 12.51 is a copper-coated solid wire with higher levels of deoxidisers (manganese and silicon). The high content of deoxidisers allows welding over heavier amounts of dirt, rust, and mill scale while providing a more fluid puddle and smoother bead profile.

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure

    ESAB Consumables FAQs

    Practical answers on choosing, storing and using welding wire and stick electrodes.

    How do I read the classification code on a stick electrode?icon-minus-redicon-plus-red

    Most stick electrodes carry a classification code on the pack, for example a letter E followed by digits. Taking a common low hydrogen code as an example: E means a stick electrode, the first two digits give the minimum tensile strength of the weld metal, the next digit shows the positions it can be used in, and the last digit tells you about the coating type and the current it needs. Extra suffixes can show a hydrogen limit or better impact toughness.

    Wire and rod codes follow their own patterns, so read the maker's data sheet or the standard named on the pack. Always match the code to the strength and type of the steel you are welding.

    How do I choose the right MIG wire diameter and shielding gas?icon-minus-redicon-plus-red

    Wire diameter and wire feed speed together set the welding current, because the wire burns off at a rate that settles in balance with the feed speed. Thicker material and higher current generally call for a larger diameter, while thin sheet suits finer wire. Your welder's manual and the wire data sheet show which diameters the machine is built for.

    For steels, typical shielding gases are carbon dioxide or argon mixed with carbon dioxide or a little oxygen. Non-ferrous metals normally use argon. The right gas depends on the wire, the metal and the transfer mode, so follow the wire maker's recommendation.

    How do I match a TIG filler rod to the metal I am welding?icon-minus-redicon-plus-red

    The weld pool is a mixture of the parent metal and the filler, so the rod is normally chosen to suit the parent metal. Carbon steel, low alloy steel and stainless each have their own rods, and low alloy heat-resistant steels need a rod made for that alloy. Using a general-purpose rod on everything is a common mistake.

    In TIG the filler is added to the weld pool by hand, separately from the arc, and argon is the usual gas for steels and stainless. Check the rod's data sheet or the standard named on its pack, and follow your welding procedure if the job is specified.

    Why are low hydrogen electrodes supplied in sealed packs?icon-minus-redicon-plus-red

    Low hydrogen electrodes are used where hydrogen cracking in the weld or heat affected zone must be avoided, such as on critical or more hardenable steels. Their coating picks up moisture from the air, which adds hydrogen to the weld. Sealed packs let you use them straight from the pack, with no baking needed beforehand.

    If a pack has been opened or damaged, the electrodes should be re-dried as the maker instructs and then kept warm or limited in their exposure time. Exact temperatures and times differ between makers, so follow the instructions on the pack and your job specification.