WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : 131724R150  

    ESAB OK Tigrod 13.17 2.4mm TIG Wire, 5Kg Pack, ER90S-B3
    131724R150

    £120.04  EX VAT
    SSP Suggested Selling Price = £130.68  YOU SAVE £10.64
     Buy in 3 easy interest free payments of £40.01† with

    OK Tigrod 13.17 is a 2.5Cr-1.1Mo-alloyed (ER90S-B3), copper-coated rod for the GMAW of creep-resistant steels like SA-387 Grade 22, A335 Grade P22 or similar materials.  The rod has a high purity chemistry with a guaranteed Bruscato factor X < 15.

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure

    Tig Er90S-B3 FAQs

    Straight answers to the questions people ask most when choosing and using 2.25Cr-1Mo chromium-molybdenum TIG filler wire.

    How does ER90S-B3 differ from ER80S-B2 and ER90S-B9?icon-minus-redicon-plus-red

    The difference is mainly the chromium and molybdenum content, which sets the base metal each one matches. ER80S-B2 is a lower-alloy wire (about 1.25% chromium, 0.5% molybdenum) for steels such as P11. ER90S-B3 steps up to about 2.25% chromium and 1% molybdenum for P22. ER90S-B9 is in a different class altogether, with about 9% chromium, for P91-type steels.

    They are not interchangeable. Using a lower-alloy filler on P22, or the reverse, is generally not accepted on code work without engineering approval.

    Do I need to preheat before welding with it?icon-minus-redicon-plus-red

    Yes. Chromium-molybdenum creep-resistant steels are prone to hydrogen cracking, so preheat is normally essential, and the interpass temperature is kept below a set maximum. The minimum preheat usually rises with thickness.

    The correct figures for your job depend on thickness, joint and the code, so always follow your qualified welding procedure. Keep the joint at temperature between passes, and do not let it cool to room temperature part-way through unless the procedure allows it.

    Does the weld need post-weld heat treatment?icon-minus-redicon-plus-red

    Almost always. Post-weld heat treatment is mandatory in most application codes for creep-resistant steels. It softens the hard as-welded structure, improves toughness and sets up the carbide structure needed for long-term creep strength. The temperature and hold time come from the procedure and code, so do not take figures from a rod description.

    Plan the heat treatment before you start welding, because it affects when the joint can be released and inspected.

    Why do data sheets for this wire quote an X factor or low impurity levels?icon-minus-redicon-plus-red

    In 2.25Cr-1Mo weld metal, trace impurities such as phosphorus, tin, antimony and arsenic can gather at grain boundaries during long periods in the 400 to 600 degrees C range. This is called temper embrittlement, and it makes the weld less tough. The X factor is a calculation from these impurities, and a lower figure means lower risk.

    A low-impurity wire with a stated X factor limit is therefore chosen for pressure equipment that will run hot for years. If your specification sets a limit, check the wire's certificate to confirm it meets it.

    Shop Similar Categories